Chapter 10: Troubleshooting the Emulator
Problems with the Emulation Module
Problems with the Emulation Module
Occasionally you may suspect a hardware problem with the emulation
module or target interface module. The procedures in this section
describe how to test the hardware, and if a problem is found, how to
repair or replace the broken component.
To run the built-in performance verification
test using the logic analysis system (Emulation
Module Only)
1
End any Emulation Control Interface or debugger sessions.
2
Disconnect the 50-pin cable from the emulation module, and plug
the loopback test board (Agilent part number E3496-66502) into
the emulation module.
3
In the system window, click the emulation module and select
Performance Verification
.
4
Click
Start PV
.
The results will appear onscreen.