User`s guide

68 MPC8240 and MPC8260 Emulation
Chapter 5: Connecting and Configuring the Emulator
Connecting the Emulator to the Target System
5 Plug the other end of the 16-pin cable into the target system.
Orient the red wire away from pin 1 of the connector and towards the
key pin. See the drawing on page 65.
CAUTION:
Be careful to orient the connector as described above. If the connector is
rotated, your target system or the emulator may be damaged.
6 Turn on the power to the logic analysis system, then turn on the
power to the target system.
To connect to a target system using an analysis
probe
1 Remove power from the target system.
2 Plug one end of the 16-pin cable into the emulator. The
connectors are keyed.
3 Plug the other end of the 16-pin cable into the connector on the
analysis probe.