You can trigger the emulation module from the logic analyzer using
either the Source Viewer window or the Intermodule window. If you are
using the Agilent Technologies B4620B Source Correlation Tool Set,
using the Source Viewer window is the easiest method.
To stop the processor when the logic analyzer
triggers on a line of source code (Source
Viewer window)
If you have the Agilent Technologies B4620B Source Correlation Tool
Set, you can easily stop the processor when a particular line of code is
reached.
1
In the Source window, click on the line of source code where you
want to set the trigger, then select
Trace about this line
.
The logic analyzer trigger is now set.
2
Select
Trace
➞
Enable - Break Emulator On Trigger
.