MPC8240 and MPC8260 Emulation 97
Chapter 7: Using the Analysis Probe and Emulation Module Together
Triggering the Emulation Module from the Analyzer
The emulation module is now set to halt the processor after receiving a
trigger from the logic analyzer.
To disable the processor stop on trigger, select Trace➞Disable -
Break Emulator On Trigger.
3
Click
Group Run
in the Source window (or other logic analyzer
window).
4
If your target system is not already running, click
Run
in the
emulation Run Control window to start your target.
To stop the processor when the logic analyzer
triggers (Intermodule window)
Use the Intermodule window if you do not have the Agilent
Technologies B4620B Source Correlation Tool Set or if you need to use
a more sophisticated trigger than is possible in the Source Viewer
window.
1
Create a logic analyzer trigger.
2
In the Intermodule window, click the emulation module icon,
then select the analyzer which is intended to trigger it.