Other MPUs on the VMEbus can interrupt, disable, communicate with and 
determine the operational status of the processor(s). One register of the GCSR 
set includes four bits which function as location monitors to allow one 
MVME166 processor to broadcast a signal to other MVME166 processors, if 
any are present. All eight registers are accessible from any local processor as 
well as from the VMEbus. 
The MVME166 provides +12 Vdc, -12 Vdc, and +5 Vdc power to the transition 
modules through fuses F1, F3, and F4. The fused +5 Vdc power is also 
provided to the 20-pin remote reset connector. These voltage sources are used 
by the transition modules to power the serial port drivers and any LAN 
transceivers connected to the transition module. The RPWR LED (DS3) on the 
MVME166 front panel lights when all three voltages are available. 
The MVME166 provides +5 Vdc to the SCSI bus TERMPWR signal through 
fuse F2, located near the front panel SCSI bus connector. The TPWR LED (DS5) 
on the MVME166 front panel monitors the SCSI bus TERMPWR signal; when 
the MVME166 is connected to an SCSI bus, either directly or via the 
MVME712-07 module, the TPWR LED lights when there is SCSI terminator 
power. Because any device on the SCSI bus can provide TERMPWR, the LED 
does not directly indicate the condition of the fuse. If the LED is not 
illuminated during SCSI bus operation, the fuse should be checked. 