User`s manual

Example Use of t167
SBCSCSI/D1 E-19
E
2. The user MUST select menu item 2 (sdlinit) prior to issuing any other
commands to the SDL. Answer with a <CR> to select the defaults as
shown below:
SDL Tools --> 2
SCSI address (7):
Interrupt level (0):
Clock frequency ('2500'):
Snoop-mode (0):
sdl_init status: 0x0
SDL Tools -->
3. The user MUST next select menu item 1 (bldsdlcs) to conÞgure for an
ATTACH command to the device prior to issuing any other commands to
the SDL. Answer as shown in the example below. The example assumes
a Wren V device.
SDL Tools --> 1
Control structure [0] (0):
Structure type (control or read/write) [c, r] (c):
Device type (direct or sequential access) [d, s] (d):
Medium type (fixed or removable) [f, r] (f):
32-bit SCSI device number (0, 0x0):
Command (0x6, ATTACH):
Supported devices:
1. Seagate Wren IV
2. Seagate Wren V
Device (1): 2
SDL Tools -->
4. To verify the command parameters prior to issuing the ATTACH
command, select menu item 6 as shown below:
SDL Tools --> 6
Control structure [0] (0):
Contents of sdl_cmd structure:
sdl_cmd.io structure type ......... sdl_cntrl
Contents of sdl_cntrl structure:
UINT dev .......................... 0x0
UINT cmd .......................... 0x6, ATTACH
UINT arg .......................... 0x1FD1AA8
UINT argp ......................... 0x1FBCE50
Device type ......................... direct-access, fixed-media
Descriptor .......................... Seagate Wren V
<CR> for more, 'q' or '.' to quit, 'x' to exit: .
SDL Tools -->
5. Now, issue the ATTACH command by selecting menu item 5.