User`s manual
siop_struc (Command Structure)
SBCSCSI/D1 B-13
B
Message-Out Buffer Pointer
This field may be modified by the Firmware.
initiator mode
If the MOBUF bit is set, the message-out pointer field contains the address
where a message to the target is placed. Normally, the user does not need to
supply any messages to send to the target. It is recommended to not set the
MOBUF bit in the command control field for normal operation; this feature of
the Firmware is intended to be used for very long extended messages. If the
MOBUF bit is cleared, this field is initialized by the Firmware.
Message-Out Bytes (0-B)
This field may be modified by the Firmware.
initiator mode
If the MOBUF bit cleared, the message-out bytes are where messages to a
target are placed.
Data Count
This field may be modified by the Firmware.
initiator mode
The data count field contains the number of bytes to be transferred during a
data phase on the SCSI bus. If no data phase is to be executed then this field
must be set to zero (0x00000000). This value must not exceed 24 bits
(0xFFFFFF or 16,777,215). If the S/G bit is set in the command control field
then this field is ignored.