Specifications

2-10
P460/P360 Memory Scanners Product Reference Guide
Using A Synapse Cable with the Scanner
1. Make sure all host devices are powered down.
IMPORTANT
Before power is provided to the scanner (step 6), the following steps must be
completed. The Synapse cable must be connected to the scanner (step 2) AND
the
flying power lead plugged in (step 4). If the cables are not connected in this
sequence, the Synapse Interface Adapter will not operate properly.
2. Connect the Synapse cable into the bottom of the scanner.
3. Connect the other end of the Synapse cable to the Synapse Interface adapter.
4. The Synapse cable has a flying power lead. Connect this lead to the receptacle in
the Synapse Interface adapter, as shown in Figure 2-9. See the Synapse guide for
details.
Figure 2-9. Synapse and Adapter Cable
5. Connect the Synapse Interface adapter to the host.
6. Connect the standard Phaser memory scanner power supply to the power
receptacle in the Synapse cable.
7. Connect the appropriate line cord to the power supply and into an AC receptacle.
8. Scan the appropriate Synapse bar codes to set up the Synapse cable for your
specifications.
Synapse Interface
Adapter (Module)
Synapse
Cable
Flying Power
Lead
To Host
To Cradle
Power Supply
Lead
Power
Receptacle