LED Codes
6
3.1.4 Fan LED
3.1.5 Temperature Status LED
Green Blinking Green Solid
Redundant System failed over and adopting
ports
Green Blinking
Alternating Green Blinking
& Amber Blinking
Redundant System not failed over.
Green Solid Amber Blinking
No License to adopt Access Ports
or
No Country Code configured on the switch
or
License and Country Code configured, but no
APs adopted
Fan LED Event
Off System Off / POST Start
Green Blinking POST in Process
Green Solid All System Fans Normal Operation
Amber Solid
Redundant Cooling Failure
System Operational
Amber Blinking
System Cooling Failure
System will be held in reset until the issue is
resolved
Temperature LED Event
Off System Off
Green Solid
Ambient Inlet Temperature is within specified
operating limit
Amber Solid
Ambient Inlet Temperature is near the maximum
operating temperature
During switch start up this LED will be lit Solid
Amber. This is normal behavior and does not
indicate an error.
System Status 1 LED System Status 2 LED Event