B-4 Event Log Messages
SURFboard Cable Modem Installation Manual
Code Event Log Messages Level Cable Modem Actions
I103.0
Required TLVs out of order.
I104.0
Required TLVs not present.
I105.0
Down Stream Frequency format invalid in
length.
4 (Error) Won’t be saved to memory
I105.1
Down Stream Frequency not in use.
I105.2
Down Stream Frequency invalid, not a
multiple of 62500Hz.
4 (Error) CM will continue reading next bytes of
Config file.
Set to 0 value
I106.0
Up Stream Channel invalid, unassigned. 4 (Error)
I106.1
Up Stream Channel Change followed with
(RE-) Registration REQ.
I107.0
Up Stream Channel overloaded.
I108.0
Network Access configuration has invalid
parameter (length).
4 (Error) Continue reading next bytes of Config
file. Set to 0 value
I109.0
Class of Service configuration is invalid.
I110.0
Class of Service ID is not in TFTP config. 7 (Info) No action taken
I111.0
Class of Service ID out of range. 4 (Error) Continue reading next bytes of Config
file. Log it. If Reg-Response returns OK,
reboot to notify CMTS the range error
I111.1
Class of Service ID invalid length 4 (Error)
I112.0
Max Downstream Bit rate configuration
has invalid length
4 (Error) Continue reading next bytes of Config
file. Set to 0 value
I112.1
Max Downstream Bit Rate configuration is
not in TFTP config.
7 (Info) Continue reading next bytes of Config
file. Set to 0 value
I113.0
Max Upstream Bit rate configuration has
invalid length
4 (Error) Continue reading next bytes of Config
file. Set to 0 value
I113.1
Max Upstream Bit Rate configuration is
not in TFTP config
7 (Info) Continue reading next bytes of Config
file.
I114.0
Up Stream Priority configuration invalid
format.
4 (Error)
I114.1
Up Stream Priority configuration setting
out of range.
4 (Error) Continue reading next bytes of Config
file.
Set to 7 value as lowest priority
I114.2
Upstream Priority configuration has invalid
length
4 (Error) Set to correct length and continue
reading next bytes of Config file.
I114.3
Vendor Spec has invalid length/type of
vendor ID
4 (Error) Set to correct length and continue
reading next bytes of Config file.
I114.4
Vendor Spec has invalid length 4 (Error) Set to correct length and continue
reading next bytes of Config file.
I115.0
Min Upstream Channel Bit Rate
configuration setting invalid length
4 (Error) Continue reading next bytes of Config
file. Set to 0 value