This section provides basic solutions for problems that installers might encounter. For additional
assistance, please contact Motorola Technical Support for a complete copy of the latest Motorola
eMTA Troubleshooting Guide.
Description of the Problem Solution
POWER
The LEDs on the power supply module and/or
the Blade(s) are not on.
• Verify that the HFC Power is properly con-
nected. (See Connecting the AC HFC Power
Source.) For more information, see “Con-
necting the AC HFC Power Source” on
page 23. Verify that F1 and F2 are installed
and not open.
• Verify that the Facility Power is properly con-
nected. For more information, see “Con-
necting the AC Facility Power Source
(Hardwire)” on page 18. Verify that F1 and
F2 are installed and not open.
• Verify that the UPS power is properly con-
nected. For more information, see “Con-
necting the UPS DC Power Source” on
page 25. Verify that F3 is installed and not
open.
The LEDs indicate abnormal on the power sup-
ply module and/or the blade(s):
• If the Power Supply AC LED is on, but the
DC LED is off, or
• The Blade Power indicator is off...
• Replace the power supply module.
• Replace the blade after verifying that the
power supply is working properly or that the
UPS input is working.
RF
• Blades cannot find the DS.
• Blades cannot complete US power ranging.
• Blades do not come on-line.
• Verify the connection and the RF input level
to the M-EMTA.
• Verify that the upstream plant is working
properly.
• Verify the provisioning server is working
properly.