Installation manual

Table Of Contents
40 MTM800 Enhanced Mobile Terminal Installation Manual INSTALLATION
Remote Mount Installation
Figure 11 Remote Mount Installation with Remote Head Enhanced/Data Expansion Head Enhanced
Table 5 Associated Components for Remote Mount
Item Description Part Number
1 Remote Mount Cable, 3 m RKN4077
2 Remote Mount Cable, 5 m RKN4078
3 Remote Mount Cable, 5 m RKN4079
4 Remote Mount Cable, 10 m PMKN4020
5 Speaker Extension Cable GMKN4084
6 Remote Head Enhanced PMLN4904
7 Data Expansion Head Enhanced PMLN4908
8 Toroid EMC Suppression Kit 01015001001
The Remote Mount Cable have to be wound 10 times
around each toroid.
Each toroid have to be placed 30.0±2.5 cm respectively
from the expansion head and the control head.
Winding at both ends reduces the effective cable length
approximately by 0.8 m.
Fix the toroids firmly to a stable surface once the Remote
Mount Cable is connected.
Transceiver
10-Pin
Connector
Remote Mount Cable
Remote Mount Enhanced
10-Pin
Connector
Remote Head
or
Data Expansion
Head Enhanced
Enhanced
Flex
Control Head
Toroid
Toroid
10x