Technical information
Nonvolatile Parameter Database
2-116 AT+i Commands Reference Manual May 31, 2008
+iAWS - Activate WEB Server Automatically
+iLATI - TCP/IP Listening Socket to Service Remote AT+i Commands
n=1-255 Host baud rate is set by dividing 3Mbps by n.
For example, if n=2, the host baud rate will be set to
3Mbps-2=1.5Mbps.
Default: 0 (host baud rate taken from BDRF parameter).
Result Code:
I/OK If n is within limits.
I/ERROR Otherwise.
AT+iBDRD? Reports the current value followed by I/OK.
AT+iBDRD=? Returns the message "0-255" followed by I/OK.
Syntax: AT+iAWS=v
Sets Activate Web Server flag to v.
Parameters: v=0 | 1 | 2 | 3
v=0 Automatic web server activation disabled.
n>0 Web server will be activated automatically when W24 goes
online in SerialNET mode or as a result of a triggered Internet
session initiation. Maximum number of concurrent browser
connections is v.
Default: 0 (Automatic web server activation disabled).
Result Code:
I/OK if v=0-3.
I/ERROR Otherwise.
AT+iAWS? Reports the current value of the Activate WEB Server flag
followed by I/OK.
AT+iAWS=? Returns the message "0-3" followed by I/OK.
Syntax: AT+iLATI=<port>
Sets the Remote AT+i service listening port number. When
connected to the Internet, opens a TCP/IP listen socket on the
local IP address and the specified port.
Parameters: port=0..65535
Command Options:
port=0 Remote AT+i service disabled.