Technical information
Report Status
2-2 AT+i Commands Reference Manual May 31, 2008
Status Message Format
Table 2-1 gives the report status message format.
AT+i!RP11 Returns a list of all ad-hoc networks available in the surrounding area.
i=14 Returns a DHCP server table of MAC and IP addresses of all the stations
connected to W24.
i=19 Returns Analog-to-Digital Converter (ADC) pin status report.
i=20 Returns a list of all APs and ad-hoc networks available in the surrounding
area.
Default: None
Result Code:
i=0..20 Status message followed by I/OK.
I/ERROR Otherwise
Table 2-1: Report Status Message Format
Report Option Format
0COnnnAD-ii
nnn – Version number; ii – Interface code: S-Serial, L-LAN, D-Dual
1IiimmmTss (<version-date>)
Iii – Interface code; mmm – Major Version; T – Version type code;
ss – Sub-version
2
Status string: "Modem data<CR/LF>"
"Command mode<CR/LF>"
"<CR/LF>Connecting to ISP<CR/LF>"
"<CR/LF>Connected to ISP<CR/LF>"
"<CR/LF>Connecting as RAS<CR/LF>"
"<CR/LF>RAS Connected<CR/LF>""<CR/LF>Closing PPP<CR/LF>"
"<CR/LF>Establishing SMTP<CR/LF>"
"<CR/LF>Sending Email<CR/LF>"
"<CR/LF>Establishing POP3<CR/LF>"
"<CR/LF>POP3 Open<CR/LF>"
"<CR/LF>Establishing HTTP<CR/LF>"
"<CR/LF>Receiving HTTP<CR/LF>"
"<CR/LF>Carrier Lost<CR/LF>"
"<CR/LF>Link Lost<CR/LF>"
3 nnmm – Boot block version number
4I/(<sock0sz>, <sock1sz>, … ,<sock9sz>)
sock<i>sz >=0 : Number of bytes pending in socket’s input buffer
<0 : Negative value of socket’s error code
5 nnnnnnnn – Hexadecimal representation of W24 serial number