Specifications
7 - 154 WiNG 5.2.6 Wireless Controller CLI Reference Guide
7.1.28 logging
config-profile config commands
Enables message logging and configures logging settings
Supported in the following platforms:
• Access Points — AP300, AP621, AP622, AP650, AP6511, AP6521, AP6532, AP71XX, AP81XX
• Wireless Controllers — RFS4000, RFS6000, RFS7000, NX9000, NX9500
Syntax
logging [aggregation-time|buffered|console|facility|forward|host|on|syslog]
logging [aggregation-time <1-60>|host <IP>|on]
logging [buffered|console|syslog|forward] [<0-7>|alerts|critical|debugging
emergencies|errors|informational|notifications|warnings]
logging facility [local0|local1|local2|local3|local4|local5|local16|local7]
Parameters
• logging [aggregation-time <1-60>|host <IP>|on]
• logging [buffered|console|syslog|forward] [<0-7>|alerts|critical|debugging
emergencies|errors|informational|notifications|warnings]
aggregation-time
<1-60>
Sets the number of seconds for aggregating repeated messages
• <1-60> – Specify a value from 1 - 60 seconds.
host <IP> Configures a remote host to receive log messages
• <IP> – Specify the IP address of the remote host.
on Enables the logging of system messages
buffered Sets the buffered logging level
console Sets the console logging level
syslog Sets the syslog server’s logging level
forward Forwards system debug messages to the wireless controller
[<0-7>|alerts|
criticail|debugging|
emergencies|errors|
informational|notificati
ons|warnings]
The following are common to the buffered, console, syslog and forward parameters. All
incoming messages have different severity levels based on their importance. The severity
level is fixed on a scale of 0 - 7.
• <0-7> – Sets the message logging severity level on a scale of 0 - 7
• alerts – Severity level 1: Requires immediate action
• critical – Severity level 2: Critical conditions
• debugging – Severity level 7: Debugging messages
• emergencies – Severity level 0: System is unusable
• errors – Severity level 3: Error conditions
• informational – Severity level 6: Informational messages
• notifications – Severity level 5: Normal but significant conditions
• warnings – Severity level 4: Warning conditions