9085_5010_04a_oi_e.docx / Feb-21 page 11 / 72
Electrical Connections
The terminal screws should be tightened with a slotted screwdriver (blade width 2mm).
DC Power Supply (X1)
The unit accepts DC supply from 18 to 30 V at the terminals X1 1 and 2. The power consumption
depends on the level of the supply voltage with aprox. 50 mA and the additional current required at
the Auxiliary Voltage Output.
All GND terminals are internally interconnected.
Auxiliary voltage output (X2)
Two auxiliary voltages (24 VDC and 5 VDC) are available as encoder / sensor supply at terminal X2
pins 7, 8 and 9. The 24 VDC output voltage depends on the device supply (see technical data).