Serial interface (X3)
A serial interface (RS232 or RS485) is available at terminal X3.
This interface can be configured in the SERIAL MENU.
The serial interface RS232 or RS485 can be used:
for easy setup and commissioning of the units
to modify settings and parameters during operation
to read out internal states and actual measuring values by PC or PLC
The following drawing shows the connection to a PC by using a standard Sub-D-9 connector:
Connection of the RS232 interface:
Connection of the RS485-interface:
Important: Parallel operation of RS232 and RS485 is not allowed!
USB interface (X7)
A serial USB interface (mini USB) is available at X7.
The USB interface can be used as follows:
For parameterization of the device during commissioning
To change parameters during operation
For reading out actual values via PC
The serial USB communication is done with a baud rate of "
115200 Baud
" and a serial data
format of "
8none1
" and cannot be changed by the user!