Control outputs (X6)
Six control outputs are available at terminal X6 pin 2, 3, 4, 5, 6 and 7.
Switching conditions can be set in the PRESELECTION MENU. The output Ctrl. Out1 – 6 are fast PNP
outputs with a switching capability of 5 – 30 Volt / 200 mA per channel.
The switching voltage of the outputs must be applied to input terminal X6 pin 1 (COM+).
In case of switching inductive loads it is advisable to use external filtering of the coils.
Wiring of the control-outputs: