Instructions
Table Of Contents
- 1. Safety Instructions and Responsibility
- 2. Compatibility Hint
- 3. Introduction
- 4. Electrical Connections
- 5. Parameter / Overview-Menu Structure
- 5.1. General Menu
- 5.2. Mode Frequency
- 5.3. Mode Counter
- 5.4. Mode SSI
- 5.5. Mode Start/Stop
- 5.6. Preselection Values
- 5.7. Preselection 1 Menu
- 5.8. Preselection 2 Menu
- 5.9. Preselection 3 Menu
- 5.10. Preselection 4 Menu
- 5.11. Preselection 5 Menu
- 5.12. Preselection 6 Menu
- 5.13. Serial Menu
- 5.14. Analog Menu
- 5.15. Command Menu
- 5.16. Linearization Menu
- 6. Appendix
9085_5010_04a_oi_e.docx / Feb-21 page 24 / 72
General Menu
MODE
This parameter specifies the selected measuring function.
0
NOT DEFINED
Operating mode: Not defined, modulation and measurement results are zero
1
FREQUENCY
Operating mode: Frequency converter, incremental signals (replaces
7085.5052)
2
COUNTER
Operating mode: Counter, incremental signals (replaces 9085.5052)
3
SSI
Operating mode: Absolute value converter, SSI signals (replaces 7386.5051)
4
START / STOP
Operating mode: Start / Stop – interface converter
ENCODER PROPERTIES
This parameter determines the characteristics of the incremental input.
(Note: Only relevant for MODE: "FREQUENCY" and MODE: "COUNTER"!)
0
RS422
RS422
1
HTL DIFFERENTIAL
HTL differential
2
HTL PNP
PNP (switch to +)
3
HTL NPN
NPN (switch to -))
4
TTL PNP
TTL PNP (switch to +)
ENCODER DIRECTION
This parameter reverses the counting or traversing direction.
0
FORWARD
Forward
1
REVERSE
Reverse
FACTOR
This parameter defines the factor with which the measurement result is multiplied.
-99999999
Smallest value
1
Default value
99999999
Highest value
DIVIDER
This parameter defines the divisor with which the measurement result is divided.
-99999999
Smallest value
1
Default value
99999999
Highest value
ADDITIVE VALUE
This parameter defines an additive constant, which is added to the measurement result.
-99999999
Smallest value
0
Default value
99999999
Highest value