9085_5010_04a_oi_e.docx / Feb-21 page 26 / 72
Mode Frequency
In this menu the operation is defined as a frequency converter (incremental signals). Depending on
the selected operating mode, only channel A or both channels (channel A and channel B) are active.
FREQUENCY MODE
This parameter determines which frequency measurement mode is desired.
0
A ONLY
Single-channel frequency measurement (only for channel A)
1
RATIO
Frequency ratio of both channels (channel B / channel A).
Note: Interpretation of the result with 4 decimal places in the format
+/- x.xxxx
2
PERCENT
Percent deviation from channel B to channel A.
Note: Interpretation of the result with 2 decimal places in the format
+/- xxx.xx %
3
A + B
Frequency addition of both channels (channel A + channel B)
4
A - B
Frequency subtraction of both channels (channel A - channel B)
5
A/B x 90°
Frequency measurement with A / B x 90 ° signal. (Forward / reverse
direction of rotation detection)
FREQUENCY BASE
Setting the desired basis for the frequency measurement (resolution).
0
1 Hz (Interpretation of the result in the format: xxxxxxxx Hz)
1
1/10 Hz (Interpretation of the result in the format: xxxxxxx.x Hz)
2
1/100 Hz (Interpretation of the result in the format: xxxxxx.xx Hz)
3
1/1000 Hz (Interpretation of the result in the format: xxxxx.xxx Hz)
SAMPLING TIME 1 (S)
The set value corresponds to the minimum measuring time (for channel A) in seconds.
The sampling time serves as a filter at irregular frequencies.
This parameter directly influences the reaction time of the device.
0,001
Shortest Sampling time
0,1
Default value
9,999
Longest Sampling time