Instructions
Table Of Contents
- 1. Safety Instructions and Responsibility
- 2. Compatibility Hint
- 3. Introduction
- 4. Electrical Connections
- 5. Parameter / Overview-Menu Structure
- 5.1. General Menu
- 5.2. Mode Frequency
- 5.3. Mode Counter
- 5.4. Mode SSI
- 5.5. Mode Start/Stop
- 5.6. Preselection Values
- 5.7. Preselection 1 Menu
- 5.8. Preselection 2 Menu
- 5.9. Preselection 3 Menu
- 5.10. Preselection 4 Menu
- 5.11. Preselection 5 Menu
- 5.12. Preselection 6 Menu
- 5.13. Serial Menu
- 5.14. Analog Menu
- 5.15. Command Menu
- 5.16. Linearization Menu
- 6. Appendix
9085_5010_04a_oi_e.docx / Feb-21 page 33 / 72
Continuation „Mode SSI“:
LOW BIT (for bit blanking)
Defines the lowest evaluated bit (MSB) for bit blanking.
If all bits should be evaluated, LOW BIT must be set to 01.
01
Smallest value
…
32
Highest value
SSI OFFSET
In the case of a „RESET/SET VALUE“ command (via control input or PC user interface) the not yet scaled,
currently acquired position value (after bit suppression and possibly performed encoder zero offset) is
transferred to the "SSI OFFSET" parameter and the display zeroed. From the new display zero point, you can
now move in positive and negative direction, depending on the direction of rotation.
(Display offset)
0
Smallest value
…
999999999
Highest value
ROUND LOOP VALUE
Defines the number of encoder steps when a round-loop function is desired.
0
Round-loop function is turned off.
…
99999999
Number of steps for the round-loop function.
SAMPLING TIME (S)
Determines the read cycle for the SSI signal in the Master MODE.
0.001
Minimum measurement time in seconds
0.010
Default value
9.999
Maximum measurement time in seconds
ERROR BIT
Defines the encoder monitoring and the error bit
0
No error bit available.
Review on connected sensor is turned off.
…
32
Position of the error bits to be evaluated
Review on connected sensor is turned on.
ERROR POLARITY
Defined the polarity of the error bit in the case of an error
0
Bit is low in the case of an error
1
Bit is high in the case of an error
Note: SSI value processing see appendix (chapter 6.5 and 6.6)