9085_5010_04a_oi_e.docx / Feb-21 page 43 / 72
Preselection 5 Menu
MODE 5
Switching conditions for preselection 5. see chapter PRESELECTION 1 MENU (except the trailing value)
See chapter PRESELECTION 1 MENU
6
RES>=PRES-TRAIL
Trailing PRESELECTION 5:
Display value is greater or equal PRESELECTION 5 PRESELECTION 2 ON,
PRESELECTION 2 is the trailing value from PRESELECTION 5
HYSTERESIS 5
This parameter defines the switching hysteresis of the switch-off point for preselection 5.
See chapter PRESELECTION 1 MENU.
PULSE TIME 5 (S)
Duration of output pulse for the switching condition of preselection 5.
See chapter PRESELECTION 1 MENU.
OUTPUT TARGET 5
Assignment of an output for the switching condition of preselection 5.
See chapter PRESELECTION 1 MENU.
0
NO
No assignment
1
CTRL OUT 1
Switching condition assigned to “Ctrl. Out 1”
2
CTRL OUT 2
Switching condition assigned to “Ctrl. Out 2”
3
CTRL OUT 3
Switching condition assigned to “Ctrl. Out 3”
4
CTRL OUT 4
Switching condition assigned to “Ctrl. Out 4”
5
CTRL OUT 5
Switching condition assigned to “Ctrl. Out 5”
6
CTRL OUT 6
Switching condition assigned to “Ctrl. Out 6”
OUTPUT POLARITY 5
Polarity for the switching condition of preselection 5.
See chapter PRESELECTION 1 MENU.
OUTPUT LOCK 5
Latch for the switching condition of preselection 5.
See chapter PRESELECTION 1 MENU.
START UP DELAY 5 (S)
Start-up suppression for the switching condition of preselection 5.
See chapter PRESELECTION 1 MENU.