9085_5010_04a_oi_e.docx / Feb-21 page 46 / 72
Continuation „Serial Menu“:
SERIAL PROTOCOL
Determines the sequence of characters send, when using the serial output for cyclic data transmission under
time control (xxxxxxx = value SERIAL VALUE).
Setting „1“ removes the unit address from the string which allows a slight faster transmission cycle.
0
Transmission report = Unit Nr., +/-, data, LF, CR
1
1
+/-
X
X
X
X
X
X
X
LF
CR
1
Transmission report = +/-, data, LF, CR
+/-
X
X
X
X
X
X
X
LF
CR
SERIAL TIMER (S)
This register determines the cycle time in seconds for cycling transmission of SERIAL VALUE when using the
serial output. (On a serial request, the cycling transmission is stopped for 20 s)
0,000
All cyclic transmission is switched off. The unit will send data upon a serial request
or with command SERIAL PRINT.
…
60,000
Cycle time in seconds.
SERIAL VALUE
This parameter defines the value to be transmitted.
Einstellung
Code
Bedeutung
0
:0
Measurement_Result (Result after linking, scaling, filter, etc.)
1
:1
Analog_Out_Voltage (Analog output modulation (in mV))
2
:2
Frequency (measured frequency - channel A without scaling)
3
:3
Frequency_2 (measured frequency - channel B without scaling)
4
:4
Counter (total count after linking without scaling, filters, etc.)
5
:5
Counter_A (counter reading - channel A)
6
:6
Counter_B (counter reading - channel B)
7
:7
SSI_Data (read + possibly converted binary SSI value)
8
:8
SSI_Calc_Result (SSI value incl. SSI zero and SSI offset without scaling,
filters, etc.)
9
:9
Minimum_Value (Minimum value of Measurement_Result)
10
;0
Maximum_Value (Maximum value of Measurement_Result)
11
;1
Analog_Out_Current (Analog output modulation (in yA))
12
;2
Analog_Out_Percentage (Percentage analog output level)
(Measurement result in xxx.x %)
13
;3
Error Status (Reading the error code)
14
;4
SSI Read Value (readed, unconverted SSI value)
15
;5
SSI Loop Value (SSI value after round loop calculation)
16
;6
Actual Speed ()
17
;7
Actual Position (Start Stop: position [in µm] with offset without scaling)
18
;8
Actual Angle (Start Stop: e.g. angle with offset without scaling)
19
;9
Raw Position (Start Stop: position [in µm] without Offset and without
scaling))