9085_5010_04a_oi_e.docx / Feb-21 page 49 / 72
Command Menu
INPUT 1 ACTION (function Input 1)
This parameter defines the function of the input “Ctrl. In 1”.
(s) = static switching (level evaluation), INPUT CONFIG must be set to active LOW / HIGH
(d) = dynamic switching (edge evaluation) ,INPUT CONFIG must be set to RISING/FALLING EDGE
0
NO
No function
1
RESET/SET VALUE
Mode “SSI”: Transfer of the currently detected position value
(after bit suppression and possibly performed encoder zero
offset shift) into the parameter "SSI offset" (display offset)
Mode “Counter”: Reset / set of both counter values (channel A
and B) to the set values in SET VALUE A u. B
Mode “Start/Stop”: Power-failure-proof stored transfer of the
current position or angle measurement to the "Offset"
parameter.
(d) (s)
2
FREEZE
Freezing of the current measurement result
(s)
3
TEACH ANALOG START
Transfer of the current measurement result in the parameter
"Analog Start"
(d)
4
TEACH ANALOG END
Transfer of the current measurement result in the parameter
"Analog End"
(d)
5
TEACH PRESELECTION 1
Transfer of the current measurement result into the parameter
"Preselection 1"
(d)
6
TEACH PRESELECTION 2
Transfer of the current measurement result into the parameter
"Preselection 2"
(d)
7
TEACH PRESELECTION 3
Transfer of the current measurement result into the parameter
"Preselection 3"
(d)
8
TEACH PRESELECTION 4
Transfer of the current measurement result into the parameter
"Preselection 4"
(d)
9
TEACH PRESELECTION 5
Transfer of the current measurement result into the parameter
"Preselection 5"
(d)
10
TEACH PRESELECTION 6
Transfer of the current measurement result into the parameter
"Preselection 6"
(d)
11
RESET MIN/MAX
Reset the minimum / maximum value
(d) (s)
12
LOCK RELEASE
Release latching of all outputs
(d)
13
SERIAL PRINT
Sending of serial data, see parameter SERIAL VALUE
(d)
14
ACTIVATE DATA
N.A.
15
STORE DATA
N.A.
16
TESTPROGRAM
N.A.
17
CLEAR LOOP TIME
Reset of the maximum “Loop Time”
(d)
18
RESET/SET COUNTER A
Mode “Counter”: Reset / set the counter value of channel A to
the set value in SET VALUE A
(d) (s)
19
RESET/SET COUNTER B
Mode “Counter”: Reset / set the counter value of channel B to
the set value in SET VALUE B
(d) (s)
20
LOCK COUNTER A
Mode “Counter”: Counter (channel A) is locked and does not
count any further pulses as long as this command is present.
(s)
21
LOCK COUNTER B
Mode “Counter”: Counter (channel B) is locked and does not
count any further pulses as long as this command is present.
(s)
22
ZERO POSITION
Mode “SSI”: Transfer of the current SSI position in the
parameter "SSI-Zero" (encoder zero offset)
(d) (s)
23
FACTORY SETTINGS
Device is reset to factory settings
(d)