Linearization Menu
The linearization function is defined in this menu. The linearization function always refers to the
scaled "Measurement Result"!
Linearization description and examples are shown in the appendix.
P1(X) … P24(X)
X-coordinate of the linearization point.
This is the value that the device would generate without linearization depending on the input signal.
-99999999
Smallest X-coordinate
0
Default value
+99999999
Largest X-coordinate
P1(Y) … P24(Y)
Y-coordinate of the linearization point.
This is the value that the device should generate instead of the x coordinate.
e.g. P2 (X) is replaced by P2 (Y).
-99999999
Smallest X-coordinate
0
Default value
+99999999
Largest X-coordinate