Compatibility Hint
This product is a successor model of the thousand fold proven converter type
9085.5052 / 7085.5052 / 7386.5051.
This converter is able to replace functionally the previous model; however some minor differences
have to be observed with regard to the parameter settings.
The main differences between this product and the respective predecessor model are listed below.
Differences of the 9085.5010 / 7085.5010 / 7386.5010 compared to the previous models are:
9085.5010 / 7085.5010 / 7386.5010
9085.5052 / 7085.5052 / 7386.5051
Incremental Input:
(9085/7085)
Possible configurations:
RS422 (TTL), HTL Differential, HTL PNP, HTL
NPN or TTL PNP (asymmetrical)
The setting made in the corresponding
parameter then applies to both inputs (A and
B).
Possible configurations:
RS422 (TTL), HTL Differential, HTL
PNP, HTL NPN or TTL (asymmetrical)
The desired setting can be made
separately for each channel (A and B)
using the corresponding DIL
switches.
Control Inputs:
Number of inputs: 6
Format: HTL
Number of inputs 1
Format: HTL
Control Outputs:
Number of outputs: 6
Format / Level: 5…30 V, PNP
Output current: max. 200 mA
Reaction time: < 1ms
No switching outputs
Encoder Supply:
Output voltage: 5VDC u. 24VDC
Output current: max. 250 mA
Output voltage: 5VDC
Output current: max. 250 mA
Serial Interface:
RS232/RS485 via screw terminals
Baud rate: 9600, 19200 or 38400 Baud
RS232/RS485 via 9-position SUB-D
connector (female)
Baud rate: 600, 1200, 2400, 4800,
9600, 19200, or 38400 Baud
Housing:
Dimensions (w x h x d): 23 x 102 x 102 mm
Weight: approx. 100 g
Dimensions (w x h x d): 40 x 79 x 91 mm
Weight: approx. 190 g
Device parameterization:
Only by operator software OS.
By operator software OS and
partially via DIL switches
Operating modes for FU:
Only channel A
Ratio B/A
Percentage deviation from channel B to A
Sum A+B
Difference A-B
A/Bx90
Only channel A
Ratio A/B
Sum A+B
A/Bx90
Only channel B
Product AxB
Difference A-B
A= Impulse, B = Direction