9.2. Technical data
Power supply AC
:
115/230 V (+/
-
12,5 %), 7,5 VA
Power supply DC
:
24 V (17
–
30 V), approx. 100 mA (without aux. sensor supply)
Ripple
:
≤
10% @ 24VDC
Total AC power
:
7,5 VA
DC current consumption
(without sensors)
:
18 V : 110 mA, 24 V : 90 mA, 30 V : 80 mA
Aux. output for sensors
:
24 V DC, +/
-
15%, 100 mA (with AC and DC power input)
Inputs
:
2 analogue inputs (+/
-
10 V, 0 ..
. +20 mA, 4 ... +20 mA)
Input impedance
:
Current: Ri = 100 Ohms, Voltage: Ri = 30 kOhms
Resolution
:
14 bits (13 bits + sign)
Accuracy
:
+/
-
0.1%, +/
-
1 digit
Switching outputs
(AX 347 only)
:
2 x PNP, max. 35 V, max. 150 mA
minimum response time 53 msec.
Serial interface
(AX 348 only)
:
RS 232 / RS 485, 600
-
38 400 bauds
Ambient temperature
:
Operation: 0°
-
45° ( 32
–
113°F)
Storage: -25° - +70° (-13 – 158°F)
Housing
:
Norly UL94
–
V
-
0
Display
:
6 decades LED, high
-
efficiency ora
nge, 15 mm (0.590’’)
Ambient temperature
:
Operation: 0°
-
45° ( 32
–
113°F)
Storage: -25° - +70° (-13 – 158°F)
Protection class
:
IP65 (front), IP20 (rear)
Screw terminals
:
Signal lines max. 1.5 mm² (.0023 sq.in.)
AC lines max. 2.5 mm² (.0039 sq.in.)
Minimum update time
:
50 msec (display)
:
53 msec (switching outputs)
Conformity and standards
:
EMC 2004/108/EC:
EN 61000
-
6
-
2
EN 61000-6-3
LV 2006/95/EC: EN 61010-1