Continuation „Preselection 1 Menu“:
PULSE TIME 1 (S)
Duration of output pulse for the switching condition of preselection 1
0,000
No output pulse (static signal)
…
60,000
Pulse duration of 60 seconds
OUTPUT TARGET 1
Assignment of an output or relay for the switching condition of preselection 1.
If more than one switching condition is assigned to one output / relay, the output is set when at least one
switching condition is true
0
NO
No assignment
1
CTRL OUT 1
Switching condition assigned to “Ctrl. Out 1”
2
CTRL OUT 2
Switching condition assigned to “Ctrl. Out 2”
3
CTRL OUT 3
Switching condition assigned to “Ctrl. Out 3”
4
CTRL OUT 4
Switching condition assigned to “Ctrl. Out 4”
5
RELAY 1
Switching condition assigned to “Rel. 1”
6
RELAY 2
Switching condition assigned to “Rel. 2”
OUTPUT POLARITY 1
Polarity for the switching condition of preselection 1
0
ACTIVE HIGH
Switching condition is true Active „HIGH“
1
ACTIVE LOW
Switching condition is true Active „LOW“
OUTPUT LOCK 1
Latch for the switching condition of preselection 1
0
NO
No latch for preselection
1
YES
Latch for preselection (command LOCK RELEASE will clear latch)
START UP DELAY 1 (S)
Start-up suppression for the switching condition of preselection 1.
This adjustment is only valid for the switching condition |RESULT|<=|PRES| or RESULT<=PRES (Start Up Delay 3
and 4 have an automatic start up suppression).
0.000
No start-up suppression
…
60.000
Start-up suppression in seconds
EVENT COLOR 1
Event-depending change of the display color for the switching condition of preselection 1.
EVENT COLOR 1 has the lowest priority. EVENT COLOR 2 … 4 are allowed to overwrite this color change.
0
NO CHANGE
No color change.
1
CHANGE TO RED
Color change to red
2
CHANGE TO GREEN
Color change to green
3
CHANGE TO YELLOW
Color change to yellow