Instructions

Ax350_04a_oi_e.doc / May-18 Seite 27 / 54
5.10 Preselection Values
This menu is used to set the preselection values or the switching points.
The preselection values / switching points are always referred to the display value.
This menu is only available for devices with option CO, A0 or RL.
PRESELECTION 1 (Preselection / switching point 1)
-99999999
Smallest value
1000
Default value
+99999999
Highest value
PRESELECTION 2 (Preselection / switching point 2)
-99999999
Smallest value
2000
Default value
+99999999
Highest value
PRESELECTION 3 (Preselection / switching point 3)
-99999999
Smallest value
3000
Default value
+99999999
Highest value
PRESELECTION 4 (Preselection / switching point 4)
-99999999
Smallest value
4000
Default value
+99999999
Highest value
5.11 Preselection 1 Menu
Switching conditions for preselection 1. Output/ relay/ display switches under the following conditions.
This function is only available for devices with option CO, AO or RL.
SOURCE 1
This parameter defines the reference source for PRESELECTION 1
0
INPUT 1
the reference source is input 1
1
INPUT 2
the reference source is input 2
2
LINKAGE 1 2
the reference source is the result of the linking of input1 and input 2
3
INPUT 1 TOTAL
the reference source is input 1 with totalization
4
INPUT 2 TOTAL
the reference source is input 2 with totalization
5
LINKAGE TOTAL
the reference source is the result of the linking of input1 and input 2 with
totalization
6
IO LINK VALUE 1
the reference source is the process data out value 1 sent by the IO-Link master
7
IO LINK VALUE 2
the reference source is the process data out value 2 sent by the IO-Link master
8
MINIMUM VALUE 1
minimum value, the reference source is input 1
9
MAXIMUM VALUE 1
maximum value, he reference source is input 1
10
MINIMUM VALUE 2
minimum value, the reference source is input 2
11
MAXIMUM VALUE 2
maximum value, he reference source is input 2