User manual

Dx34510b_oi_e.doc / Jun-15 Page 16 / 42
5. Setup Procedure
For better understanding the following sections 4.1 and 4.2 explain settings related to the display
only. Model-specific settings for Analog Output, Preselection’s and Serial Link will be explained
separately under sections 5.3 to 5.5, later.
5.1. Basic Settings
These settings in general have to be carried out one time only upon the very first use of the unit.
The basic setup selects the desired operation mode of the unit, the input characteristics
PNP/NPN and the desired brightness of the LED display.
To access the Basic Setup press ENTER and SET simultaneously for at least 3 seconds.
Menu
Setting Range
Default
Operation Mode:
Tachometer, frequency meter (5.2.1)
Baking time / processing time indicator (5.2.2)
Timer, Stopwatch (5.2.3)
Counter for position or event (5.2.4)
Speed calculation from
differential transition time (5.2.5)
Switching characteristics of the inputs:
NPN, switch to “-
PNP, switch to “+“
Brightness of the LED display:
20%, 40%, 60%,
80%, 100%
100%