User manual
Dx34510b_oi_e.doc / Jun-15 Page 22 / 42
5.2.5. Speed from differential time between a Start and a Stop input
Input A operates as a start input and input B operates as a Stop input. The differential time
between start and stop will be converted into the speed of the passing object.
Menu
Setting Range
Default
Time:
Enter a typical delay time which you expect between
the start and stop signals.
000.001
…
999.999 sec
1.000 sec
Display Value:
Enter the speed you would like to see in the display
when an object passes within above time.
000.001
…
999.999
1.000
Decimal Point:
Select the desired position like shown in the display.
000.000
no decimal point
000000
done decimal position
00000.0
---->
five decimal positions
0.00000
Wait Time
How long should the last result remain in the display
before it returns to zero? Set the desired waiting time.
With setting “0” the display will freeze and wait until to
the next measuring cycle.
0.00
...
9.99
1.00
5.2.6. Linearization points
The linearization points will only appear with Operation Modes "RPM" or "Count" when
Linearization is enabled.
Menu
Setting Range
Default
P01_X
Linearization point 1:
X value of the first interpolation point.
-199999
... 999999
999999
P01_Y
Linearization point 1:
Y value of the first interpolation point.
-199999
... 999999
999999
…
…
P16_X
Linearization point 16:
X value of the 16. interpolation point.
-199999
... 999999
999999
P16_Y
Linearization point 16:
Y value of the 16. interpolation point.
-199999
... 999999
999999
For more details about linearization please refer to section 6.1