The following operational parameters provide setting of the switching points:
Menu
Setting Range
Default
Preselection 1:
-199999...
999999
10000
Preselection 2:
-199999...
999999
5000
The working direction of the Hysteresis depends on the setting of the switching characteristics.
With settings „GE“ or „LE“ respectively, the following switch points will result:
Preselection
Hysteresis
GE=Greater/Equal
Display Value
Hysteresis effect with "Greater / Equal"
Preselection
LE=Lower/Equal
Hysteresis
Display Value
Hysteresis effect with "Lower / Equal"
It is possible to check up on the actual switching state of the outputs at any time.
For this, just tap on the ENTER key shortly.
The display will then show for the next two seconds one of the following information:
Display
Meaning
Both outputs are actually off.
Both outputs are actually on.
Output 1 is on.
Output 2 is off.
Output 1 is off.
Output 2 is on.