User manual
Dx34510b_oi_e.doc / Jun-15 Page 30 / 42
Units with serial link also allow setting or resetting the counter by serial command (similar to the
external input or front key function). To activate the Reset command, please write “1” to register
code “60”. To release the Reset command again, write “0” to the same register.
The following strings show how to set or reset a unit with unit No. 11:
Reset ON :
ASCII
EOT
AD1
AD2
STX
C1
C2
Data
ETX
BCC
Hex
04
31
31
02
36
30
31
03
34
Binary
0000
0100
0011
0001
0011
0001
0000
0010
0011
0110
0011
0000
0011
0001
0000
0011
0011
0100
Reset OFF :
ASCII
EOT
AD1
AD2
STX
C1
C2
Data
ETX
BCC
Hex
04
31
31
02
36
30
30
03
35
Binary
0000
0100
0011
0001
0011
0001
0000
0010
0011
0110
0011
0000
0011
0000
0000
0011
0011
0101
For more details about serial communication please refer to the separate document "SERPRO"