User manual

Dx34510b_oi_e.doc / Jun-15 Page 13 / 42
3.3. Teach Operation
The Time-Out Function remains disabled during all Teach operations
Key
Function
ENTER will conclude or abort any Teach operation in progress
SET function is fully similar to normal set-up operation
Cmd will store the display value to the register and will change over to the next
interpolation point.
For details of the Teach procedure see section 5.2.
3.4. Set All Registers to “Default“
At any time you can return all settings to the factory default values.
This action will reset all parameters to factory default values and your own
settings will be lost. You will have to repeat your individual setup procedure.
Factory default values are shown in the subsequent parameter tables.
To reset the unit to default values:
switch power off
press the ENTER key on the front
keep ENTER down while you power up again
3.5. Code Locking of the Keypad
When the code locking of the keypad has been switched on, any key access first results in display
of
To access the menu you must press the key sequence
within 10 seconds, otherwise the unit will automatically return to the normal display mode.