User manual

Dx34510b_oi_e.doc / Jun-15 Page 19 / 42
5.2.2. Time, display of baking or processing time (reciprocal speed)
(Input A = frequency input, Input B not in use)
Menu
Range (OS)*
Default
Display Format:
Select between seconds, minutes, minutes and seconds
or minutes with two decimal positions. This will also
automatically set your decimal point to the proper
place.
Seconds
Minutes
Minutes and seconds
Minutes with two decimal positions
Frequency:
Set a typical operating frequency for your application.
1 Hz to
25 000 Hz
100
Display Value:
Set the value you would like to see on your display with
above frequency at the input.
1 ... 999999
100
Wait Time:
Define a “waiting time“, this is the time in seconds that
the unit will wait from one input pulse to the next,
before it sets the display to zero. When you enter “0“,
the unit will wait forever and show the last result until
it receives the next input.
0.1 … 99.9 s
5.0
The setting of this parameter automatically limits the minimum input
frequency correspondingly. With “Wait” set to e.g. 0.1 sec. the unit will
respond to frequencies > 10 Hz only and all lower frequencies will just
display 0.
Average Filter
Selectable averages filter to suppress unstable display
with unsteady input frequencies.
No filtering
2, 4, 8, 16 = number of floating average cycles.
*) OS only with DX348
(0)
(1)
(2)
(3)
(0)
(1)