5.1 General Menu
OPERATIONAL MODE
This parameter specifies the selected measuring function.
0
SPEED
Speed indicator (RPM), tachometer or frequency counter
1
PROCESS TIME
Operation as baking time or processing time indicator (reciprocal speed)
2
TIMER
Operation as stopwatch
3
COUNTER
Operation as position indicator, event-, sum-, differential- or up-down counter
4
VELOCITY
Runtime measurement as speed indicator
ENCODER PROPERTIES (for DX350)
This parameter determines the characteristics of the pulse input for DX350.
0
PNP
PNP (switch to +)
1
NPN
NPN (switch to -)
2
NAMUR
Connect sensor () to GND and sensor (+) to input (A or B)
3
TRI-STATE
Tri-State for push-pull encoders/ sensors
ENCODER PROPERTIES (for DX355)
This parameter determines the characteristics of the pulse input for DX355.
0
RS422
RS422 standard
1
HTL DIFFERENTIAL
HTL differential
2
HTL PNP
HTL PNP single ended (switch to +)
3
HTL NPN
HTL NPN single ended (switch to -)
ENCODER SUPPLY (only for DX355 available)
This parameter defines the voltage of the auxiliary supply output (Aux-Out).
0
24VDC SUPPLY
24 VDC encoder supply
1
5VDC SUPPLY
5 VDC encoder supply
COUNTING DIRECTION
This parameter determines the direction of counting. (Only in mode COUNTER)
0
FORWARD
forward
1
REVERSE
reverse