Instructions

Dx350_05a_oi_e.doc / Mai-18 Seite 19 / 51
Continuation „General Menu“:
LINEARIZATION MODE
This parameter defines the linearization function. See chapter 6.1.
0
OFF
No linearization
1
1 QUADRANT
Linearization in the 1. quadrant
2
4 QUADRANT
Linearization in all 4 quadrants
PIN PRESELECTION
This parameter defines the PIN-code to lock the quick start of the menu PRESELECTION VALUE for entering the
preselection values. (Master PIN 6079).
This Lock function is only useful in conjunction with active lock function in PIN PARAMETER.
0000
No lock
9999
Access after entering PIN-Code 9999
PIN PARAMETER
This parameter defines the PIN-code for lock function of all parameters (master PIN 6079).
0000
No lock
9999
Parameterization of the unit after entering PIN-code 9999
BACK UP MEMORY
0
NO
No back memory up by power failure
1
YES
Backup memory by power failure, actual value will be saved
FACTORY SETTINGS
0
No
No default values are loaded
1
Yes
Load default values of all parameters (grey marked default values)