Instructions

Dx350_05a_oi_e.doc / Mai-18 Seite 22 / 51
Continuation Mode Speed“:
FOR/REV DETECTION
This parameter enables the detection of direction of rotation (Input A, Input B with 90°)..
0
OFF
Direction of rotation detection off
1
ON
Direction of rotation detection on
5.3 Mode Process Time
In this menu the operation is defined as baking time or processing time indicator (reciprocal speed)
Only input A is used. This menu is only displayed when the appropriate OPERATIONAL MODE in the
GENERAL MENU is selected.
DISPLAY FORMAT
This parameter selects the Display Format. The corresponding decimal point will be set automatically.
0
SECONDS
Display in seconds
1
MINUTES
Display in minutes
2
MIN:SEC
Display in minutes : seconds
3
MIN.00
Anzeige in Minuten und 1/100 Minuten
4
H:M:S
Anzeige in Stunden : Minuten : Sekunden
DISPLAY VALUE
Desired value, which should be displayed at the setting of BASE FREQUENCY.
1
Smallest value
1000
Default value
99999999
Highest value
BASE FREQUENCY (HZ)
Reference frequency for the desired DISPLAY VALUE.
1
Smallest value
100
Default value
500000
Highest value
SAMPLING TIME (S)
The configured value corresponds to the minimum measurement time. The Parameter is used as a filter in case of
irregular frequencies. This parameter directly affects the response time of the unit.
0.005
Shortest sampling time
0.1
Default value
9.999
Longest sampling time