Instructions

Dx350_05a_oi_e.doc / Mai-18 Seite 24 / 51
5.4 Mode Timer
In this menu the operation of timer or stopwatch is defined.
Depending on the parameterization only input A or both are used. This menu is only displayed when the
appropriate OPERATIONAL MODE in the GENERAL MENU is selected.
TIME BASE
This parameter defines the time base or resolution of the measurement.
0
1/1000 SEC
Milliseconds
1
1/100 SEC
1/100 seconds
2
1/10 SEC
1/10 seconds
3
SECONDS
Full seconds
4
MIN.00
Minutes and 1/100 minutes
5
MIN.0
Minutes and 1/10 minutes
6
H:M:S
Hours : Minutes : Seconds (9999:59:59)
7
H:M
Hours: Minutes (999999:59)
START / STOP
This parameter defines the start/stop condition of the time measurement.
0
COUNT AT A HIGH
Time measurement active at Input A is „HIGH“
1
COUNT AT A LOW
Time measurement active at Input A is „LOW“
2
START A / STOP B
A rising edge at Input A starts the time measurement,
a rising edge at Input B stops the time measurement.
3
PERIODE AT A
Period time measurement:
displays the time between two rising signal edges at Input A
AUTO SET /RESET
0
NO
Time measurement works adding or subtracting, there is no automatic set/reset at
next start. Start setting must be done via set/reset
1
YES
With each start, the new time measurement starts automatically at the set value of
the parameter "SetValue".
LATCH-FUNCTION
0
NO
Real time display, counting value is visible.
1
YES
Display shows the result of the last measurement.
The time counts in the background.
SET VALUE.
In case of a set / reset command (via keyboard shortcut, control input, or PC user interface), the timer is set to SET
VALUE.
0
Smallest value (Reset)
99999999
Highest value
INC / DEC MODE
When START/STOP is setting to period time measurement, the time measurement works always adding.
0
INCREMENT MODE
time measurement works adding
1
DECREMENT MODE
time measurement works subtracting