Instructions

Dx350_05a_oi_e.doc / Mai-18 Seite 25 / 51
5.5 Mode Counter
In this menu the operation as position indicator, impulse counting, sum of 2 inputs, difference of 2 inputs
or up-down counter is defined. Input A and Input B are used. This menu is only displayed when the
appropriate OPERATIONAL MODE in GENERAL MENU is selected.
COUNT MODE
This parameter defines the counter operation.
0
A SINGLE
Input A is a counting input. Input B defines the counting direction:
„LOW“ = forward „HIGH“ = reverse
1
A+B
Sum counter: Impulses at A + Impulses at B
2
A-B
Differential counter: Impulses at A impulses at B
3
A/B 90 x1
Quadrature counter: Impulses A, B with edge counting x1
4
A/B 90 x2
Quadrature counter: Impulses A, B with edge counting x2
5
A/B 90 x4
Quadrature counter: Impulses A, B with edge counting x4
FACTOR
Scaling factor. With the summing mode (A+B) and the differential mode (A-B) please note
that the impulse scaling factor will only affect input A
For example: A setting of factor 1.23456 and 100000 input pulses will result in a value of 123456.
0.00001
Smallest value
1
Default value
99.99999
Highest value
SET VALUE
In case of a reset command (via keys, Control-Inputs or PC-user interface), the counter is set to the value entered
here.
-99999999
Smallest value
0
Default value
+99999999
Highest value
DECIMAL POINT
This value defines the position of the decimal point.
0
NO
No decimal point
1
0000000.0
Decimal point at the specified position
2
000000.00
Decimal point at the specified position
3
00000.000
Decimal point at the specified position
4
0000.0000
Decimal point at the specified position
5
000.00000
Decimal point at the specified position
6
00.000000
Decimal point at the specified position
7
0.0000000
Decimal point at the specified position