Instructions

Dx350_05a_oi_e.doc / Mai-18 Seite 27 / 51
Continuation „Mode Velocity“:
BASE TIME (S)
Reference time for the desired DISPLAY VALUE.
0.001
Smallest value
1
Default value
999.999
Highest value
DECIMAL POINT
This value defines the position of the decimal point.
0
NO
No decimal point
1
0000000.0
Decimal point at the specified position
2
000000.00
Decimal point at the specified position
3
00000.000
Decimal point at the specified position
4
0000.0000
Decimal point at the specified position
5
000.00000
Decimal point at the specified position
6
00.000000
Decimal point at the specified position
7
0.0000000
Decimal point at the specified position
WAIT TIME (S)
This parameter defines the period time of the lowest frequency, accordingly the time between two rising signal
edges detecting frequency 0 Hz. Frequencies with a period time higher than the set “WAIT TIME” will be detected
as frequency = 0 Hz.
0.00
The display value is retained until a new value is determined.
0.01
Frequency = 0 Hz, for frequencies below 100 Hz
99.99
Frequency = 0 Hz, for frequencies below 100 Hz
STANDSTILL TIME
This parameter defines the time setting for standstill definition.
A time of xx.xx seconds after detection " frequency = 0 Hz " the unit signals "standstill" and reactivates the start-up-
delays. Stand still detection can be set in PRESELECT MENU.
This STANDSTILL TIME is suitable at WAIT TIME unequal 0.000 only.
0.00
Shortest time
99.99
Longest time