Instructions

Dx350_05a_oi_e.doc / Mai-18 Seite 37 / 51
5.14 Command Menu
INPUT 1 ACTION (function Input 1)
This parameter defines the function of the input “Ctrl. In 1”.
0
NO
No function
1
RESET/SET VALUE
Mode Timer: Reset the value to 0.
Mode Counter: Reset / set the value to „SET VALUE“.
Mode Velocity: Reset the value to 0.
(d) (s)
2
FREEZE
Freeze actual display value
(s)
3
KEY LOCK
disable touch screen
(s)
4
LOCK RELEASE
Loosen locking of all outputs / relay
(d)
5
RESET MIN/MAX
Reset of the min. / max. values
(d) (s)
6
SERIAL PRINT
Sending of serial data, see parameter SERIAL VALUE
(d)
7
TEACH PRESEL. 1
Current display value is stored as PRESELECTION 1
(d)
8
TEACH PRESEL. 2
Current display value is stored as PRESELECTION 2
(d)
9
TEACH PRESEL. 3
Current display value is stored as PRESELECTION 3
(d)
10
TEACH PRESEL. 4
Current display value is stored as PRESELECTION 4
(d)
11
SCROLL DISPLAY
Display switching (see display in operation mode)
(d)
12
CLEAR LOOP TIME
Release all latched switching conditions
13
START PRESELECT
N.A.
14
ACTIVATE
N.A.
15
STORE DATA
N.A.
16
TESTPROGRAM
N.A.
17
SET RED COLOR
The display lights up red. The color can be changed by the event-
dependent color switching in the PRESELECTION 1... 4
(d)
18
SET GREEN COLOR
The display lights up green. The color can be changed by the event-
dependent color switching in the PRESELECTION 1... 4
(d)
19
SET YELLOW COLOR
The display lights up yellow The color can be changed by the event-
dependent color switching in the PRESELECTION 1... 4
(d)
20
INCREMENT BATCH
Increase the batch counter (see mode counter)
(d)
21
DECREMENT BATCH
Decrease of the batch counter (see mode counter)
(d)
22
RESET/SET BATCH
Reset the batch counter (see mode counter)
(d)
(s) = static switching (level evaluation)
INPUT CONFIG must be set to active LOW / HIGH
(d) = dynamic switching (edge evaluation)
INPUT CONFIG must be set to RISING/FALLING EDGE