The following Operational Parameters provide configuration of the serial interface:
Menu
Setting Range
Default
Serial Timer:
Setting 0,000 allows manual activation of a serial data
transmission at any time. All other settings specify the cycle
time for automatic transmission, when the interface is set to
"Printer Mode"
0,000
0,010 sec
9.999 sec
0,100 sec
Between two transmission cycles the unit will allow a pause
depending on the baud rate. The minimum cycle times for
timer transmissions are shown in the table.
Baud Rate Minimum Cycle Time [ms]
600 384
1200 192
2400 96
4800 48
9600 24
19200 12
38400 6
Serial Mode:
PC: Operation according to communication profile
(see 4.5.1)
Print1: Transmission of string type 1 (see 4.5.2)
Print2: Transmission of string type 2 (see 4.5.2)
Serial Register-Code:
100
...
120
101
Specifies the register code of the data to be transmitted.
The most important register codes are:
Register S-Code ASCII Description
Original SSI
Value
111 ; 1 Direct encoder data
SSI Value 113 ; 3 Encoder data after
Bit Blanking
Display
value
101 : 1 Value with full scaling
as it appears in the
display