7.2. Technical Specifications
Supply voltage AC : 115/230 V (+/- 12.5 %)
Supply voltage DC : 24 V (17 – 30 V)
Consumption (without sensor) : 17 V: 190 mA, 24 V: 150 mA, 30 V: 120 mA
AC Power : 7.5 VA
Aux. output for encoder : 24 VDC, +/- 15%, 120 mA (with AC and DC supply)
Control Inputs : 3 inputs, A, B, C (PNP/NPN/Namur)
Input currents : 5.1 mA / 24 V (Ri = 4,7 kOhm)
Input level HTL : Low: 0 ... 2 V, High: 9 ... 35 V
SSI input frequency range : 100 Hz – 1 MHz
Min. pulse duration for Reset : 5 msec
Analogue output (IX 346) : 0/4 ... 20 mA (max. 300 ohms), 0...+/-10 V (max. 2 mA)
Resolution : 14 Bits + Sign
Accuracy : 0.1%
Serial interface (IX 348) : RS 232 / RS 485, 600 to 38 400 bauds
Ambient temperature : Operation: 0° - 45°C ( 32 – 113°F)
Storage: -25° - +70°C (-13 – 158°F)
Housing : Norly UL94 – V-0
Display : 6 decades, LED, high- efficiency orange, 15 mm (0.59’’)
Protection class : Front IP65, Rear IP20
Terminal cross section : Signals max. 1.5 mm², AC power max. 2.5 mm²
Switching outputs (IX 347) : PNP, max. 35 volts, max. 150 mA
Conformity and Standards : EMC 2004/108/EC: EN 61000-6-2
EN 61000-6-3
LV 2006/95/EC: EN 61010-1