1. Terminal Assignment
IX 345: Display unit only
All connections are as shown below, except for terminals 8, 9 and 10 which are unconnected
IX 346: Display with analogue output
GND
17-30 VCD IN
1 2 3 4 5 6 7 8 9
10
Input A
Input B
GND
+24 VDC OUT
GND analogue
+/- 10 V analogue
0/4-20 mA analogue
PE
GND
230VAC
115 VAC
0 VAC
C
L
K
C
L
K
D
A
T
D
A
T
1 2 3 4
Input C (Reset)
IX 347: Display with two presets and outputs
GND
17-30 VCD IN
1 2 3 4 5 6 7 8 9
10
Input A
Input B
Input C (Reset)
GND
+24 VDC OUT
COM+
OUT 1
OUT 2
PE
G
N
D
2
3
0
V
A
C
1
1
5
V
A
C
0
V
A
C
C
L
K
C
L
K
D
A
T
D
A
T
1 2 3 4
IX 348: Display with serial interface
GND
17-30 VCD IN
1 2 3 4 5 6 7 8 9
10
Input A (transm.)
Input B
Input C (Reset)
GND
+24 VDC OUT
TxD / B (-)
PE
GND
230VAC
115 VAC
0 VAC
C
L
K
C
L
K
D
A
T
D
A
T
1 2 3 4
GND
RxD / A (+)