User Manual-for Mac

MOTU SMPTE SETUP
123
The 896mk3 cannot freewheel address without
clock. Therefore, the Freewheel Address setting will
always be lower than or equal to the Freewheel
Clock setting, and both menus will update as
needed, depending on what you choose.
The ‘Infinite freewheel setting
The Infinite freewheel setting in the Freewheel
Clock menu causes the 896mk3 to freewheel
indefinitely, until it receives readable time code
again. To make it stop, click the Stop Freewheeling
button.
Stop Freewheeling
The Stop Freewheeling button stops the system if it
is currently freewheeling.
GENERATOR SECTION
The Generator section (on the right-hand side of
the window in Figure 10-1) provides settings for
generating SMPTE time code.
Level
Turn the level knob to adjust the volume of the
SMPTE time code being generated by the 896mk3.
The level knob disappears when the Destination is
set to None.
Tach light
The Tach light blinks once per second when the
896mk3 is generating SMPTE time code.
Destination
In the Destination menu, choose either SMPTE (to
generate time code) or None (to turn it off).
Stripe
Click this button to start or stop time code. To set
the start time, click directly on the SMPTE time
code display in the Generator section and type in
the desired start time. Or drag vertically on the
numbers.
Figure 10-2: Setting the time code start time.
Regenerate
This option, when enabled, causes the generator to
generate time code whenever the 896mk3 is
receiving SMPTE time code.
Generate from sequencer
This option, when enabled, causes the generator to
generate time code whenever you are running
AudioDesk or Digital Performer. time code begins
at the time specified by the AudioDesk or Digital
Performer main transport.
SETTING UP FOR SMPTE TIME CODE SYNC
To set up direct SMPTE time code synchroni-
zation, see “Syncing to SMPTE time code on
page 34.
RESOLVING DP OR AUDIODESK TO TIME
CODE
To resolve Digital Performer or AudioDesk directly
to time code with no additional sync devices, use
the setup shown in “Syncing to SMPTE time code
on page 34. Choose Receive Sync from the Setup
menu and choose the Sample accurate option.
Make sure that the Slave to External Sync command
in the Studio menu is checked. Make sure the Clock
Source setting in the MOTU Audio Setup window
is set to SMPTE. Also, make sure that youve
connected an LTC input signal to the 896mk3 time
code input, and that you’ve specified that input in
SMPTE Source menu in SMPTE Setup.
Click here to edit
the start time, or
drag vertically
on the numbers.
896mk3 Hybrid book Page 123 Friday, August 19, 2011 1:44 PM