User Manual-Windows

INSTALLING THE PCI-424 HARDWARE
40
SAMPLE-ACCURATE ADAT SYNC
This page shows an ideal setup for using the
PCI-424 and a 2408mk3 interface with one or more
ADATs, Alesis hard disk recorders or any ADAT
SYNC-compatible devices. Connect the PCI-424
card to the end of the ADAT chain and make the
software settings as shown below in Figure 4-20.
This setup is also ideal if you have both Alesis and
Tascam decks. If so, connect your Tascam
equipment to the Digital Timepiece as directed in
the Digital Timepiece manual.
For ADAT optical digital mixers, see “Syncing
ADAT ‘lightpipe devices” on page 48.
Windows computer running Cubase or
other sample-accurate ASIO software
Digital Timepiece, MIDI Timepiece AV, Alesis BRC or
any other MMC-compatible ADAT synchronizer
USB cable (or other bi-
directional MIDI connec-
tion) bearing MMC trans-
port commands from
Cubase (or other ASIO
software) to the Digital
Timepiece (or other
synchronizer)
Figure 4-20: Connections for sample-accurate ADAT sync.
ADATs
or ADAT SYNC-compatible recorders
Sync In
ADAT
sync cables
Sync Out
Sync In
Sync Out
Sync In
Sync Out
etc.
ADAT
Sync Out
PCI-424 card
ADAT Sync In
In Cubase VST, go to the Synchronization window and
choose ASIO 2.0 MMC as the Timecode Base. In Cubase SX,
go to the Synchronization Setup window and choose the
ASIO Positioning Protocol and MIDI Machine Control options.
1. In the MOTU PCI Audio Console, choose PCI-424: ADAT from the Clock
Source menu as shown to above.
2. Make sure the Sample Rate setting matches the other recorders.
Ta sc am
Sync Out
Optional
Tascam sync
chain
If you have a DTP or
MTP AV, set their sync
mode to Internal.
Put Cubase into external sync mode.
See “Sample-accurate sync with Cubase or
Nuendo” on page 80 for more information.
Use this setup if you have:
ADATs, Alesis hard disk recorders or any ADAT SYNC
compatible device(s).
A MOTU Digital Timepiece, MIDI Timepiece AV or other
ADAT synchronizer.
Host software that supports sample-accurate sync.
This setup provides:
Sample-accurate locating between all ADAT SYNC-compati-
ble devices, the 2408mk3 and your software (Cubase or other
sample-accurate software).
With a Digital Timepiece, this setup provides sample-accurate
locating across all devices: ADAT, Tascam and the 2408mk3.
Transport control of everything from the computer, OR
continuous sync to SMPTE time code and other sync sources
(the other source is the transport master in this case).