OPERATION MANUAL CLASSIC PLUS 14 and CLASSIC PLUS 26 FIRST-CLASS MAIL PERMIT NO. 8390 LONG BEACH, CA BUSINESS REPLY MAIL DENSO SALES CALIFORNIA, INC. 3900 VIA ORO AVENUE LONG BEACH CA 90810-9969 DENSO SALES CALIFORNIA, INC. 3900 Via Oro Avenue Long Beach CA 90810-1868 800-264-9573 / 310-834-6352 www.movincool.
LIMITED WARRANTY The aforesaid warranty is the only warranty made by DENSO with respect to the Products and is in lieu of all obligations or liabilities on the part of DENSO for damages arising out of or in connection with the sale, use or performance of the Products, including, without limitation, any lost profits or any other consequential, incidental, special or exemplary damages of any kind.
OPERATION MANUAL CLASSIC PLUS 14 and CLASSIC PLUS 26
ii
TABLE OF CONTENTS FOREWORD ............................................................................................ 1 Definition of Terms .......................................................................... 1 GENERAL WARNINGS & CAUTIONS .................................................... 2 INVENTORY & ASSEMBLY .................................................................... 3 Inventory ........................................................................................... 3 Assembly .....
iv
FOREWORD Congratulations on purchasing the MovinCool portable air conditioner. This manual explains how to assemble, install, operate, and maintain the MovinCool Classic Plus 14 and Classic Plus 26 portable air conditioning units. Please read this operation manual thoroughly to familiarize yourself with the features of the unit and to ensure years of reliable operation. You may also find it useful to keep this operation manual on hand for reference.
GENERAL WARNINGS & CAUTIONS • All electrical work, if necessary, should only be performed by qualified electrical personnel. Repair to electrical components by non-certified technicians may result in personal injury and/or damage to the unit. All electrical components replaced must be genuine MovinCool parts, purchased from an authorized reseller. • The proper electrical outlet for MovinCool units must be equipped with a UL approved ground-fault breaker to prevent electrical shock from the unit.
INVENTORY & ASSEMBLY Inventory After unpacking your MovinCool unit, please check to make sure you have the following items: ❏ Classic Plus 14 or Classic Plus 26 MovinCool Unit (1) ❏ Cool Air Outlet Ducts (2) ❏ Screws (8) ❏ Operation Manual/Warranty Card (1) NOTE: If any of these items were not included in the box or appear damaged, please contact your MovinCool reseller for replacement.
INVENTORY & ASSEMBLY Assembly CAUTION: Before assembling make sure the unit is on a flat, level surface and the casters are in the LOCKED position. (Both the Classic Plus 14 and Classic Plus 26 MovinCool units have locking swivel casters in the front only.) UNLOCKED LOCKED Install each cool air outlet duct using 4 screws each as shown. NOTE: Do not overtighten the screws when installing the cool air outlet ducts. This could damage the base on the cool air outlet duct assembly.
INSTALLATION Choosing and Installation Site CAUTION: Following are some precautions to consider before choosing your installation site. Please review carefully as improper installation may result in personal injury or damage to the unit. • Do not use the unit in areas where leakage of flammable gas may occur. • Do not use the unit in areas where it will be exposed to rain or water. • Do not use the unit in an atmosphere of excessively corrosive gas or vapor.
INSTALLATION (cont.) Moving the Unit Unlock the casters and push the MovinCool unit from the front panel edge to a flat, level surface and set the casters back to the LOCKED position.
INSTALLATION (cont.) Plugging in the Unit • Check the prongs and surface of the power cord plug for dust/dirt. If dust and/or dirt are present, wipe off with a clean, dry cloth. • Check the power cord, plug and prongs for damage or excess play. If any damage or excess play is found, contact your MovinCool reseller for repair. • For the Classic Plus 26 model, fully insert plug into the A/C outlet and rotate clockwise until it locks in place.
FEATURES Both models feature: • An electronic control panel which allows the user to control the unit’s operation easily. • Dual fan speeds (either High or Low) in both COOL and Fan Only modes. • A digital display that indicates the temperature SET POINT (either Fahrenheit or Celsius) in which the COOL Mode will operate. This is also the local temperature the unit will try to maintain. The Temperature Set Point can be adjusted by the SET TEMP buttons (▼/▲).
OPERATION Control Panel Before operating the unit, it is important to familiarize yourself with the basic controls located on the control panel. SET TEMP FAN ON/OFF COOL ON/OFF Classic Plus ➀ COOL ON/OFF Button Activates/deactivates the COOL mode/ turns the unit off. ➁ FAN ON/OFF Buttons Activates/deactivates the HIGH or LOW fan mode. ➂ SET TEMP Buttons (▼/▲) Increases/decreases the temperature set point. ➃ TANK FULL LED Flashes when the drain tank is full.
OPERATION (cont.) Operating in COOL Mode The unit can be operated in COOL mode by pressing the COOL ON/OFF button (LED illuminates). NOTE: In COOL mode the unit can only be turned off by pressing the COOL ON/OFF button again, not by pressing the fan buttons. ➀ Change the fan speed by pressing the HIGH or LOW fan buttons. ➁ Change the temperature set point by pressing the SET TEMP buttons (▼/▲).
OPERATION (cont.) Operating Modes Both Classic Plus models operate in 2 modes, FAN Only and COOL. When in FAN Only mode the unit circulates the surrounding air. When in COOL mode, the compressor is engaged and cool air is circulated. ■ COOL Mode Both models will operate in FAN Only mode for approximately 120 seconds before the compressor engages (compressor time delay program is 120 + 10 seconds).
OPERATION (cont.) Emptying the Drain Tank During COOL mode, condensate will accumulate in the drain tank. When the drain tank becomes full, the FULL TANK LED will flash and the unit will shut off automatically. NOTE: If you want to empty the drain tank, while the unit is in operation, press the COOL ON/OFF button to turn the unit off. ➀ Pull the drain tank from the unit. ➁ Remove the cap and empty the drain tank. ➂ Replace the cap and return the drain tank to the unit.
OPERATION (cont.) DRAIN PUMP KIT (Optional) (Classic Plus 14 model ONLY) A drain pump kit (CPK-3) is available to allow continuous operation and to eliminate the need for a drain tank. • When the water collects to level (A) in the pump reservoir, the drain pump begins to operate and discharge the water. A B NOTE: The compressor will not operate while the drain pump is discharging water. • When the water level drops below level (B), the drain pump stops, and the compressor will restart.
OPERATION (cont.) DRAIN PUMP KIT (Optional) (Classic Plus 26 model ONLY) A drain pump kit (CPK-4) is available to allow continuous operation and to eliminate the need for a drain tank. • • When the water collects to level (A) in the pump reservoir, the drain pump begins to operate and discharge the water. B A When the water level drops below level (B), the drain pump stops, and the compressor will restart.
DAILY INSPECTION & MAINTENANCE Emptying the Drain Tank To empty the drain tank, refer to instructions on page 12. Cleaning the Air Filters Clean the air filters once a week. If the unit is used in a dusty environment, more frequent cleaning may be required. A dirty air filter reduces air output resulting in a decrease in cooling capacity. Filter Removal Method (both models) ➀ Turn the unit off, by pressing the COOL ON/OFF button. ➁ Remove the 3 air filters.
DAILY INSPECTION & MAINTENANCE (cont.) In-Season/Off-Season Inspection & Maintenance ■ In-Season ➀ Check the prongs and surface of the power cord plug for dust and/or dirt. If dust and/or dirt are present, wipe off with a clean, dry cloth. ➁ Check the power cord, plug and prongs for damage or excess play. If any damage or excess play is found, contact your MovinCool reseller for repair. ➂ Check the air filters and drain tank.
TROUBLESHOOTING Self-Diagnostic Codes Self-Diagnostic Codes will be displayed on the Control Board under the following conditions: Code Condition dF When the evaporator thermistor disengages the compressor. FL When the drain tank switch shuts off the unit (FULL TANK LED flashes). AS When unit disengages the compressor while the condensate pump is discharging water. HP When the high pressure switch disengages the compressor.
TECHNICAL SPECIFICATIONS MODEL ITEM/FEATURES Classic Plus 14 Classic Plus 26 Rating Conditions dry bulb wet bulb humidity 95 oF (35 oC) 83 oF (28.3 oC) (60%) 95 oF (35 oC) 83 oF (28.3 oC) (60%) Specifications power frequency line voltage, single phase power consumption current consumption power factor starting current power cord 60Hz 115 V 1.41 Kw 12.3 Amps 95% 32A 14 (3-core) AWG 60Hz 208/230V 3.37/3.24 Kw 16.8/14.
LIMITED WARRANTY The aforesaid warranty is the only warranty made by DENSO with respect to the Products and is in lieu of all obligations or liabilities on the part of DENSO for damages arising out of or in connection with the sale, use or performance of the Products, including, without limitation, any lost profits or any other consequential, incidental, special or exemplary damages of any kind.
OPERATION MANUAL CLASSIC PLUS 14 and CLASSIC PLUS 26 FIRST-CLASS MAIL PERMIT NO. 8390 LONG BEACH, CA BUSINESS REPLY MAIL DENSO SALES CALIFORNIA, INC. 3900 VIA ORO AVENUE LONG BEACH CA 90810-9969 DENSO SALES CALIFORNIA, INC. 3900 Via Oro Avenue Long Beach CA 90810-1868 800-264-9573 / 310-834-6352 www.movincool.