Switch User Manual

EDS-508 Series User’s Manual Specifications
B-2
Power
Input Voltage 12 to 48 VDC, redundant inputs
Input Current (@24V) 0.29A: (EDS-508)
0.43A: (EDS-508-MM-SC, EDS-508-SS-SC)
Connection Two removable 6-pin terminal blocks
Overload Current
Protection
Present, can withstand 1.6A
Reverse Polarity
Protection
Present
Mechanical
Casing IP30 protection, aluminum case
Dimensions 80.5 x 135 x 105 mm (W x H x D)
Weight 1.04 kg
Installation DIN-Rail, Wall Mounting (optional kit)
Casing IP30 protection, aluminum case
Environment
Operating Temperature 0 to 60°C (32 to 140°F)
-40 to 75°C (for "-T" models)
Storage Temperature -40 to 85°C (-40 to 185°F)
Ambient Relative
Humidity
5% to 95% (non-condensing)
Regulatory Approvals
Safety UL60950, UL 508, CSA C22.2 No. 60950,
EN60950(E212360)
Hazardous Location UL/cUL Class I, Division 2, Groups A, B, C and D (E238559).
ATEX Class I, Zone 2, EEx nC IIC (03CA24537)
EMI FCC Part 15, CISPR (EN55022) class A
EMS EN61000-4-2 (ESD), Level 3
EN61000-4-3 (RS), Level 3
EN61000-4-4 (EFT), Level 3
EN61000-4-5 (Surge), Level 3
EN61000-4-6 (CS), Level 3
Shock IEC60068-2-27
Freefall IEC60068-2-32
Vibration IEC60068-2-6
MTBF 260,000 hours
WARRANTY 5 years