User`s manual
IA260-261-262 EM-2260 LX User’s Manual  Getting Started 
Powering on the IA260/IA261/IA262/EM-2260 
Connect the SG wire to the shielded contact located in the upper left corner of the 
IA260/IA261/IA262/EM-2260, and then power on the computer by connecting it to the power 
adaptor. It takes about 60 seconds for the system to boot up. Once the system is ready, the Ready 
LED will light up. 
NOTE  After connecting the IA260/IA261/IA262/EM-2260 to the power supply, it will take about 60 
seconds for the operating system to boot up. The green Ready LED will not turn on until the 
operating system is ready.
ATTENTION 
This product is intended to be supplied by a Listed Power Unit and output marked with “LPS” 
and rated 12-48 VDC, 580 mA (minimum requirements). 
Connecting the IA260/IA261/IA262/EM-2260 to a PC 
There are two ways to connect the IA260/IA261/IA262/EM-2260 to a PC: through the serial 
console port or via Telnet over the network. Or, you can use a monitor connected to the VGA 
output of the IA260/IA261/IA262/EM-2260 to connect directly to the computer. 
Debug Port 
The debug port gives users a convenient way of connecting to IA260/IA261/IA262/EM-2260. This 
method is particularly useful when using the computer for the first time. Debug port is useful for 
connecting IA260/IA261/IA262/EM-2260, so you do not need to know either of its two IP 
addresses in order to connect to the debug port. 
Use the debug port settings shown below. 
Baudrate 
115200 bps 
Parity 
None 
Data bits 
8 
Stop bits: 
1 
Flow Control 
None 
Terminal 
VT100 
2-2